The water in a large lake is to be used to generate electricity by the installation of ahydraulic turbine-generator at a location where the depth of the water is 50 m. Water isto be supplied at a rate of 5000 kg/s. If the electric power generated is measured to be1862 kW and the generator efficiency is 95 percent, determine(a) the overall efficiency of the turbinegenerator,(b) the mechanical efficiency of the turbine,(c) the shaft power supplied by the turbine to the generator.(a. 0.760 b. 0.8 c. approximate 1960 kW)…
Mechanical efficiency of the turbine